GLP BT Battery Tester for Electric Vehicles

Highly efficient system for testing individual cells or cell blocks with manual or automatic set up as required. Standard base device for manual workstations and expandable with flexible pre-configurated modules for automated production lines


GLP2-BT High voltage battery tester

The Key Technical Data

Test methods:
  • Insulation resistance up to 1000VDC in 4-wire technique.
  • High Voltage DC test up to 3.5 kV and 1 mA/3 mA potential free in 4-wire technique.
  • *no polarity +/- switch over integrated in the base device.

Test connectors

  • 10-pin HAN-ECO Harting plug at rear.
  • 2 Pole 4mm pole sockets for insulation resistance.
  • 2 HV-socket terminals for HVDC.
  • Standard external control protocol is SCPI.